SR-D76861 · Issue 544606

Job Scheduler will be stopped by node shutdown detection

Resolved in Pega Version 8.5

LifeCycle Job Scheduler was trying to start already stopped background services during node shutdown, causing exceptions to be logged. This has been resolved by stopping Job Scheduler execution when node shutdown is detected.

SR-D84099 · Issue 547825

Atmosphere library updated

Resolved in Pega Version 8.5

Multiple setAttribute exceptions were logged related to the Atmosphere component, indicating "The request object has been recycled and is no longer associated with this facade." Investigation showed that since the request object was destroyed, an illegalstateexception was thrown. To resolve this, the Atmosphere library has been updated to version 2.4.5.7 which contains the fix for this error.

SR-D66222 · Issue 529636

Tracer expiration set for five minutes

Resolved in Pega Version 8.5

Tracer was not terminating on tracer window closure. On the next attempt to open a trace, a message appeared stating "Cannot Launch Multiple Tracer Sessions for a requestor. This requestor is being traced by operator". Tracer session termination was dependent on the browser executing code on window close. Because this event may not be triggered for number of reasons, updates have been made to set tracer session expiration at 5 minutes. In addition, the system will clean up expired sessions before checking for existing sessions.

SR-D70569 · Issue 538509

Tracer retains modified user settings

Resolved in Pega Version 8.5

User settings in tracer were not shown when the settings window was closed and reopened. Investigation showed that settings are filtered based on watchInsKey, but this parameter was passed as "null" for global tracer because of a missing condition to check the session type. This has been resolved by adding a check so the WatchInsKey parameter is passed if the session type is rule watch.

SR-D84190 · Issue 547174

Post-Import Migration Agent query optimized

Resolved in Pega Version 8.5

A Post-Import Migration agent belonging to the Pega-ImportExport Ruleset and set to run every 60 seconds by default triggered the SQL query "select ASTERISK from pegadata.pca_CWT_CXP_Work_Interaction" which ran for an excessive amount of time, caused a utilization spike, and then crashed the utility nodes. Investigation showed the excessive run time and load was caused by the query fetching a very large number of results. To better handle this scenario, the query usage has been updated.

SR-D46133 · Issue 534650

Colon in folder or file name will be replaced with underscore during unzip

Resolved in Pega Version 8.5

After creating a product file (zip), attempting to import the same file into an updated system resulted in an exception. Investigation showed that in this case the zip file was a Product rule form which had applications packaged with a colon(:) in the name of the application, a format that was allowed in 6.x versions. Because Windows machines restrict creating creating any folder or file with : in its name, the zip file could not be inflated as part of the import process. To resolve this, the system has been updated so that a colon(:) will be replaced by underscore(_) during inflate operations.

SR-D84364 · Issue 551401

Check for circular references added to SearchInventoryImpl to prevent recursive call

Resolved in Pega Version 8.5

An out of memory error was traced to SearchInventoryImpl infinitely recursing over a clipboard property, where the child property referenced a parent property and resulted in an endless loop. This has been resolved with the addition of a depth check to ensure that the search does not recurse infinitely.

SR-D85745 · Issue 545905

DASS and DAS associated to the Pega-ProcessCommander Ruleset

Resolved in Pega Version 8.5

An upgrade was failing at the point of Pega Rules Upgrade in the Installer Instance with the error "Encountered database exception when preprocessing deferred operations <insert updatesCache instance DATA-ADMIN-SYSTEM PEGA not only if new>. This node not found in the database - Either the record was never saved or was deleted. Unable to join the cluster." This error occurred because the strategic application import during upgrade manually included a "systemname" DASS instance which had a value other than "prpc". This caused a override of the platform shipped DASS (with value "prpc), which is required by the upgrade. In order to avoid this condition, DASS and DAS have been associated to the Pega-ProcessCommander Ruleset.

SR-D81572 · Issue 551027

JDBC URL handling added for Oracle over TCPS

Resolved in Pega Version 8.5

While attempting to upgrade an environment over TCPS, the generateDDL.sh script was failing. The same environment ran without issue on Tomcat with the same URL. Investigation showed the JDBC url was not correctly generated while running the upgrade: in a standard scenario, there will be no spaces in the JDBC URL specified. However, because Oracle can send spaces as part of JDBC URL and cause this issue, an update has been made which will quote the JDBC URL argument for the ant target in setupDDL.xml.

SR-D83053 · Issue 544269

SameSite cookie setting added for Mashup support in Google Chrome v80+

Resolved in Pega Version 8.5

"The Google Chrome browser version 80 and above now treats SameSite with a blank value as "Lax" by default, causing mashup scenarios to break. In order to compensate for this change, support has been added for setting SameSite=None in Cookie Settings; this value automatically includes the “secure” cookie flag, which enforces HTTPS for the Pega server and mashup. For mashups to work, SameSite should be set as None. Create a Dynamic system setting in the Pega-Engine RuleSet with the name “security/csrf/samesitecookieattributevalue” and the value "None" and restart the server. (The SameSite value "None" works only in secure HTTPS connections.) Note: The SameSite cookie may be set to None/Lax/Strict, based on the requirement. For cookie requirements other than mashup, it should be set as either Strict or Lax, depending upon your application."