INC-142589 · Issue 595489

Corrected tooltip evaluation for multiselect

Resolved in Pega Version 8.4.3

After adding help text for a multiselect help icon with overlay on hover field, the value was not being sourced. Changing to a different type of help text or control type worked as expected. This was due to an error in case sensitivity, using pyToolTip when it should have been pyTooltip, and has been corrected.

INC-142714 · Issue 596554

Recent Cases from different applications available to open

Resolved in Pega Version 8.4.3

An enhancement has been added which will allow opening other application assignments in the Recent Cases section of the current application when the user has access to multiple applications.

INC-143005 · Issue 596954

Fluid Overlay displays as expected in Firefox

Resolved in Pega Version 8.4.3

After upgrade, using the Overlay format "Fluid" to perform the screening matches task in CLM using Firefox had an overlay that covered the entire screen but was missing the scrollbar to manage the content. This has been resolved by adding changes to support dynamic content (with scrollbar) for center overlay.

INC-163292 · Issue 635837

Portlet service deprecated

Resolved in Pega Version 8.4.6

Portlet authentication services have been removed from the standard installation package.

INC-173068 · Issue 654064

HTML tags escaped in Audit History field values

Resolved in Pega Version 8.4.6

The case narrative section was showing case statuses with encoded special characters such as % or ( ), resulting in entries such as "Status changed to Complete &# 40;approved& #41; !@#$ %^& amp;*&# 40;&# 41;_&# 43;.". This has been resolved by updating the PyMemo field from type Text Input to DisplayAsLiteral for case narrative, which matches the setting for case history.

INC-175882 · Issue 658642

Updated bulk action audit history logic and security

Resolved in Pega Version 8.4.6

After update, using the standard bulk action feature did not record an audit history entry for the SLA action on a case. This was traced to changes made around authorization for opening worklists when using pzBulkProcessItem that limited the audit history to reassign, transfer or transfer assignment, and has been resolved by updating the login the Work-pzBulkProcessItem activity. In addition, the Require authentication to run checkbox has been enabled on the Security tab of the activity, and the Allow invocation from browser checkbox has been disabled.

INC-177183 · Issue 660537

Refresh assignment checks updated

Resolved in Pega Version 8.4.6

Additional privilege checks have been added to refresh assignment.

INC-178650 · Issue 673550

Cross-site scripting protections updated

Resolved in Pega Version 8.4.6

Cross-site scripting protections have been updated around the DisplayAttachment function.

INC-183947 · Issue 673735

Query split added to handle Oracle expressions limit

Resolved in Pega Version 8.4.6

The PXCHECKFLOWDEPENDENCIES activity was throwing the Oracle error message "ORA-01795: maximum number of expressions in a list is 1000" when a case had a very large number of sub-cases, causing a failure in trying to submit additional child cases which sent them into the broken process. This has been resolved by updating the pxCheckFlowDependencies rule to break down the query parameter into batches of 999 so they can be handled by Oracle.

INC-184271 · Issue 668414

Portal Header persists appropriately

Resolved in Pega Version 8.4.6

The Portal header was disappearing immediately after case attachments were opened from the right sidebar and did not reappear even after refresh. This was traced to the absence of pd(event), and has been resolved by adding pd(event) to the onclick attribute in the anchor tag in the attachment UIKit rules.