INC-142589 · Issue 595489
Corrected tooltip evaluation for multiselect
Resolved in Pega Version 8.4.3
After adding help text for a multiselect help icon with overlay on hover field, the value was not being sourced. Changing to a different type of help text or control type worked as expected. This was due to an error in case sensitivity, using pyToolTip when it should have been pyTooltip, and has been corrected.
INC-142714 · Issue 596554
Recent Cases from different applications available to open
Resolved in Pega Version 8.4.3
An enhancement has been added which will allow opening other application assignments in the Recent Cases section of the current application when the user has access to multiple applications.
INC-143005 · Issue 596954
Fluid Overlay displays as expected in Firefox
Resolved in Pega Version 8.4.3
After upgrade, using the Overlay format "Fluid" to perform the screening matches task in CLM using Firefox had an overlay that covered the entire screen but was missing the scrollbar to manage the content. This has been resolved by adding changes to support dynamic content (with scrollbar) for center overlay.
INC-178650 · Issue 673549
Cross-site scripting protections updated
Resolved in Pega Version 8.6.3
Cross-site scripting protections have been updated around the DisplayAttachment function.
INC-183947 · Issue 673734
Query split added to handle Oracle expressions limit
Resolved in Pega Version 8.6.3
The PXCHECKFLOWDEPENDENCIES activity was throwing the Oracle error message "ORA-01795: maximum number of expressions in a list is 1000" when a case had a very large number of sub-cases, causing a failure in trying to submit additional child cases which sent them into the broken process. This has been resolved by updating the pxCheckFlowDependencies rule to break down the query parameter into batches of 999 so they can be handled by Oracle.
INC-184816 · Issue 674434
Added handling to find the workparty for FixCorrespondence
Resolved in Pega Version 8.6.3
Using a Send Email smart shape and triggering email by passing the target email ID instead of the workparty role triggered the email as expected, but if a fix correspondence flow was initiated due to some error during the transaction, it was not possible to resubmit the fix flow action. Investigation showed that this was due to the fix correspondence flow check using the party role, which had not been passed. This has been resolved by updating the corrUpdate and createAndProcessCorr activities to copy the pyCorrPage from NotifyOp which contains the getgetEmailSenderInfo and use it to set pyCorrPage.pyStreamType.
INC-186036 · Issue 685371
Field Level Audit updated to handle hierarchical properties
Resolved in Pega Version 8.6.3
Field Audit was not working for the first change of the data selected/provided for a field. The audit was only reflected after the second change was made. When the property involved a series of hierarchies, for example pageprop.pagelist(1).pageprop, the FLA objects will initially use deferred saves and the generated pzinskeys will be added to a savedFLAMap object. However, when the last pageprop was not eligible to save, all the deferred saves of earlier records were cancelled but the inskeys were not removed from the savedFLAMap object. Because of this, the parent FLA records were assumed to have been saved already when those saves were actually deferred. This was a missed use case for hierarchical properties, and has been resolved by adding an update to remove the inskeys from the savedFLAMap object so that in the subsequent property change the audit's FLA records for the parent properties (pageprop.pagelist(1)) will be saved again.
INC-189186 · Issue 673661
Updated error handling in AddAttachmentFromMail
Resolved in Pega Version 8.6.3
Attachments links were still showing in case attachments even if the files were not uploaded to the repository. This was traced to the system not skipping code related to attaching files when there were errors on the attachment page, and has been resolved by updating AddAttachmentFromMail to perform this skip.
INC-189622 · Issue 682099
Cleaned up references to deprecated property type
Resolved in Pega Version 8.6.3
While using the Pega API to update a case from one application to another, an error was generated indicating the system was unable to find a property definition of “caseTypeClass” in pyAddableWorkList of the workpage. All properties in the clipboard pages of the work page are validated during this update: in this case, the check was for the caseTypeClass property, which is no longer used but which was on the clipboard page. To resolve this error, all remaining references to property casetypeclass have been removed.
INC-190819 · Issue 682000
Wrapper added to set correct bulk transfer context
Resolved in Pega Version 8.6.3
Bulk transfer was not working as expected when transferring an assignment from a flow defined in data class. Investigation showed the bulk transfer UI was getting picked from work- class while the post processing was running under data class context: this has been resolved by creating a wrapper activity in baseclass to call the post processing activity Work- .