INC-146780 · Issue 602025

Updated ArchivedCaseHistory visibility

Resolved in Pega Version 8.4.4

After enabling case archiving on Pega Cloud, it was possible to search the cases from case manager studio, but the audit details were missing. Previously Audit History was directly displayed based on whether archival was enabled or not. As part of Field Level Audit, a new property called pyHistoryViewType was introduced which is a prompt list with ALL and FIELD as its values. This property checks whether FLA is enabled or not, and based on that value ALL is set. In this case, because FLA was not enabled, the pyHistoryViewType property was empty and the HISTORY tab was not shown. To resolve this, the pyArchivedCaseHistory section table 2 visibility condition has been updated.

INC-147658 · Issue 604686

Handling added for Top and Primary page references in flow action

Resolved in Pega Version 8.4.4

After upgrade, if a flow action had a class of the section which was different from the class of the flow action, the DXAPI code retrieved the section as the same class of the flow action and not the class defined in the flow action. In flow action, the section was configured be rendered in the context of page reference as Top, however, this was not handled so the section was resolved in the context of primary page. This has been resolved by adding the missing handling for Top and Primary page references in flow action.

INC-148747 · Issue 613876

Helper text set for radio buttons in DX API

Resolved in Pega Version 8.4.4

The api/v1/assignments/{ID}/actions/{actionID} Service Rest was not rendering the tooltip into DXAPI converted JSON for Radio Button Helper Text. This was traced to a missing Tooltip check in the API Rule-Utility-Function for radio buttons, and has been resolved.

INC-148817 · Issue 604971

Added check for ABAC policy to getassignmentdetailsinternal

Resolved in Pega Version 8.4.4

When an attribute based access control (ABAC) policy was defined on a particular class, the policy was properly applied when browsing instances of the class and directly opening the work object. However when an associated assignment was processed via the DXAPI (using the assignments service) the security was not applied and users who should not have access were able to progress the case. This has been resolved by adding a check in the pzgetassignmentdetailsinternal activity to check for work object opening security.

INC-149823 · Issue 608354

DX API returns properly referenced icon class for embedded page

Resolved in Pega Version 8.4.4

When using the DX API to build an Angular JS UI, the response returned from the GET /cases/{ID}/actions/{actionID} api did not return the iconStyle for an icon class that uses a property reference when the flow is on an embedded page. This has been resolved by adding code to set the correct context for pzAPICreateJsonForModes and pzAPICreateJsonForField Rule-Utility-Function.

INC-150172 · Issue 611774

Updated class handling for View field security

Resolved in Pega Version 8.4.4

When using a defined View which returned a page and its fields and used an inherited custom work party definition, trying to update the pyWorkParty(Customer) by calling the "post /assignments/{ID}/{actionID}" did not work as expected when Field Security was ON. This was traced to the field security relying on the design time page class information stored in the list/group property, and has been updated to resolve the view fields using actual class information from the work page.

INC-152442 · Issue 616668

Check added for Create Access to attachment

Resolved in Pega Version 8.4.4

After restricting access for the attachments category in a CS application, the attachment was added without category and could not be opened. This was due to the Create Attachment access not being automatically created for all categories when privileges were added, and has been resolved by adding a step to check Create Access for attachments of the respective category.

INC-153688 · Issue 616919

Class name length limitation raised to 64 characters

Resolved in Pega Version 8.4.4

In order to support field audits on very long class names, FLAudit Class has been modified to allow a class Name length of 64 characters instead of the previous limit of 56.

INC-154189 · Issue 617247

Harness used to determine read-only for button/text input

Resolved in Pega Version 8.4.4

If a button/text input was configured to always be editable in a section by using the /v1/cases/{ID}/pages/{pageID} API (say i.e PageID as Review), the button/text input was always returned as readonly. This was due to the API being hardcoded to return readonly info, and has been resolved by updating pzGetPageDetails to not force read-only and let the harness configuration decide the behavior.

INC-154826 · Issue 614818

Enhanced handling for screen/non-screen/screen flow movement

Resolved in Pega Version 8.4.4

When using a screen flow where the last screen had a link to launch a section, a cancel button in the section that was configured with a data transform and a 'Finish Assignment' intended to move back to the screen flow did not work as expected. If a browser refresh was performed and then the cancel button was clicked, the Finish Assignment / return was triggered as expected. Because this configuration navigated to a non-screen flow, the attachOnLoad function did not load the parameter needed for maintaining error messages. This has been resolved by updating the navigation to handle this use.