INC-207996 · Issue 709664

Check added for parent case dependency if deferred-save is used

Resolved in Pega Version 8.7.2

After updating the status of a parent case to "Pending-ChildCaseDependency", the wait shape for the child case that should have been triggered by the status did not work and the child case remained on hold. This was a missed use case for the pxCheckFlowDependencies activity where defer-save operations on Index-AssignDeps class was not considered, and may happen when the Queue Processor is evaluating the dependencies while instances to Index-AssignDeps are not committed yet. To resolve this, code has been added to check the entry of the parent case dependency in deferred-save if its not present in Index-AssignmentDeps table.

INC-208394 · Issue 713552

Error handling updated for Data-Work-Attach-File

Resolved in Pega Version 8.7.2

If a file is uploaded which has the same name as an existing case attachment or if any issue happens during file attachment, the attachment will fail and an error message is displayed with an option to cancel the operation. However, even if the upload was not successful the related Data-WorkAttach-File instance was created and persisted in the Workattach table. Investigation showed this was caused by the process for persisting the Data-WorkAttach-File record occurring prior to the process that returns the errors, and this has been resolved.

INC-209404 · Issue 710407

MultiFilePath supports file upload with leading special character

Resolved in Pega Version 8.7.2

Updates have been made to the pzMultiFilePath control in order to support uploading a file with a special character such as "%" at the beginning of the name.

INC-210680 · Issue 712071

Updated logic for setting param.PrimaryPage in transfer

Resolved in Pega Version 8.7.2

TransferAssignment was failing intermittently when doing routing either by background processing or manual transfer. Investigation showed this was caused by a null param.PrimaryPage value which resulted in a NullStepPage exception. This has been resolved by adding a Property-Set method just before calling the activity pxTransferAssignment. In addition, the "Require authentication to run" check box in the pxTransferAssignment activity has been set to on.

INC-210787 · Issue 710394

Multiple child case assignments open correctly in Ajax container

Resolved in Pega Version 8.7.2

After configuring two cases with a parent-child relationship, the child case was configured with a parallel process with two assignments. When trying to open the child case assignments in an Ajax container, only the first assignment would open. Investigation showed this was caused by the "reloadAlways" parameter not being sent to openAssignment due to a custom control being used. To resolve this, the reloadAlways has been added as an argument to the OpenAssignment function call in pyAssignmentsLabel.

INC-212896 · Issue 711189

Resume Flow will print Flow Action Label in audit history

Resolved in Pega Version 8.7.2

After calling Resume Flow for processing the assignments, when the Assignment was processed the Flow Action Name was printed on the Audit History instead of Flow Action Label. Investigation showed that in the Complete assignment activity, there was no code in the 'if' loop to set the value of actionLabel. If the value was null, the property set in the next step sets actionLabel to flowActionID and the audit history result is FlowAction ID instead of FlowAction Label. To resolve this, logic has been added in the CompleteAssignment Activity step 5 to set ActionLabel with Flow Action Label.

INC-215354 · Issue 712664

Data- flow actions working in Bulk Process

Resolved in Pega Version 8.7.2

When trying to render a flow action whose 'applies to' class was inherited from Data-, an error was generated indicating that the flow action could not be found. This was traced to non Work- flow actions not being correctly populated, and was an inadvertent side effect of work done to set class for inheritance if Work- is not present. This has been resolved by updating the pzPreBulkProcessModal activity to set the TempWorkPage class to Work- only if .pyActionName is pyTransferAssignment.

INC-215499 · Issue 714487

Assignment routing updated for swimlanes

Resolved in Pega Version 8.7.2

Routing options were not working for workbasket routing when using swimlanes. Investigation showed that when an assignment was added inside the swimlane, the assignment type value was defaulting to Worklist on submit of the assignment property panel. Manually changing it to workqueue did not make the routing section visible. This has been resolved by adding a 'visible when' condition to the "Route To" field to check if the assignment is not in the swimlane. The same check has been added to a 'disable when' condition for the 'Assignment type' drop down.

INC-
218457 · Issue 713986

Updated debug logging

Resolved in Pega Version 8.7.2

Debug logging within IndexReferenceSynchronizer and FastLoader has been updated. With this update, IndexReferenceSynchronizer debug logging will indicate what the action is for each instance, FastLoader will include information about the keys being loaded and statements being executed, and duplicate logging has been removed from BatchSQLExecutors.

INC-202004 · Issue 705170

Hotfix documentation updated to point to Hotfix Manager page

Resolved in Pega Version 8.7.2

The readme file attached to hotfix downloads contained an outdated reference to use "PRPC Hotfix Installer on the Update Manager landing page." This has been updated to point to the Hotfix Manager landing page.