INC-202480 · Issue 699082
Resolved report filter section freeze
Resolved in Pega Version 8.6.4
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
SR-B70379 · Issue 326388
Post-printing screenshot window freeze fixed
Resolved in Pega Version 7.3.1
When an attached screenshot was clicked open and displayed in a pop-up window, the window was freezing after a print operation was performed. This was an issue with closing the ActiveX control through Microsoft Internet Explorer. To resolve this, the ActiveX control previously used has been changed to Silverlight.
SR-B51005 · Issue 312076
Fixed error pop-up and freeze for idled session
Resolved in Pega Version 7.3.1
The error pop-up window was appearing after a session idled for 30 minutes, displaying the message "There has been an issue - please contact the system administrator" and the session would freeze. This was caused by a null property error and has been fixed.
SR-B77544 · Issue 326629
Scroll bar issues fixed for freeze column pane
Resolved in Pega Version 7.3.1
A vertical scroll bar was displayed on the screen and the horizontal scroll was not working as expected when the freeze column pane option was selected in the repeating grid. This was traced to styles missing from the base-grids.css that were needed for fixed column configuration, and these have been added.
INC-208199 · Issue 706447
bbbAdded input null check to resolve loading error
Resolved in Pega Version 8.6.4
The application was freezing while loading if action was taken on the controls while a page level message was visible. This has been resolved by adding an additional null check for input before calling the focus API.
SR-B32323 · Issue 309342
Fixed SC toggling for Interaction Driver
Resolved in Pega Version 7.3.1
Two buttons on the interaction driver - 'Add Task' and 'Submit' - were freezing after more than one service case was created and the user toggled between two service cases. This has been fixed by modifying the code to handle scenarios where an onclick attribute is already present for a link.
SR-D49507 · Issue 521413
Support added for Oneof/AllOf association prefix in ABAC policies
Resolved in Pega Version 8.4
The Report browser was freezing when attempting to save a report with an association rule where ABAC policies prevented access to one of the classes in the association. This has been resolved by updating the system to append the correct prefix in cases where the ABAC rule has Oneof/Allof Functions so the association is resolved correctly.
SR-D52144 · Issue 515673
When no active document is available on login, first document will be marked active
Resolved in Pega Version 8.4
After logging into the user portal, attempting to perform operations like (opening a case/work object, opening reports etc.) caused the browser request to spin or freeze. The only way to recover was to close and re-launch the browser window/session and re-login. This issue occurred when there was an active reportdefinition document before the browser/node crash in the tabless dynamic container(DC) portal. After recovery, the dynamic container did not recreate the report definition document but instead tried to activate the first document in the portal, which in this case was the default harness configured in the Dynamic Container. As it was not yet loaded, exceptions were thrown. To resolve this, when no active document is available, the first document will be marked as the active document.