INC-150407 · Issue 605840

Validation error messages correctly cleared in nested markup

Resolved in Pega Version 8.5.2

A UI Freeze issue was seen whenever mandatory input was missed and the form was submitted. Continuing was possible after browser refresh, but a new Next>> button appeared. This was an unintended side effect of work done to correctly clear validation messages when areas had captions, and has been resolved by modifying that work so it performs as expected on nested markup.

INC-150472 · Issue 607392

Sorting works after selecting a view on GRID

Resolved in Pega Version 8.5.2

After configuring an optimized table with personalized view, saving a view and toggling to the new view, the sorting on the grid did not work anymore. Returning to the default view did not fix the problem, but sorting was reenabled after a browser refresh. This was traced to duplicate removeinstance calls of the grid which deleted the click event listeners for sort, and has been resolved.

INC-150189 · Issue 608911

Handling added for new doc.write with Google Chrome 85

Resolved in Pega Version 8.5.2

Document.write was not working as expected on Google Chrome 85 due to the DOM elements not being updated. This has been resolved by updating the code to do doc.write by checking the if the document body has no child nodes in a time out.

INC-135335 · Issue 588510

Parent flow next step will take precedence over sub-process

Resolved in Pega Version 8.5.1

A Breadcrumb configured in the screen flow was not displaying at the last assignment when there were multiple embedded sub processes and the last assignment was called in a sub process. This was traced to the parent flow next step information not being passed due to the next step in the sub process being marked as an end shape. To resolve this, the pzFlowSteps7 html control has been updated to pass the parent flow's next step information in this situation.

SR-D77719 · Issue 569769

OpenIfStale updated to resolve optimistic locking race condition

Resolved in Pega Version 8.5.1

A race condition was created in optimistic locking by having two assignments save at overlapping times. This has been resolved by modifying the pzShowConflicts activity to use a version of openIfStale which will consider a workpage as stale even if the difference in pxUpdateDatetime is in milliseconds.

INC-134912 · Issue 581326

Handling updated for wait shapes with different outgoing connector flow actions

Resolved in Pega Version 8.5.1

After configuring a flow with a wait shape that by default used the pyContinueAfterWait flow action for the outgoing connector of the wait shape refer, adding any other valid flow action resulted in the error "Action To Take must be a valid flow action for this assignment". This was due to the post-processing of the connector properties modal updating the ActionToTake value based on wait shape, so that changing the flow action on a connector caused the validation on save to fail if the ActionToTake on wait shape and the connector flow action did not match. To resolve this, the system has been modified to validate a wait shape with different flow action on the outgoing connector.

SR-D59283 · Issue 523207

Check added for WorkParty property to catch changes

Resolved in Pega Version 8.5.1

After configuring a send email shape to send email to work parties, proceeding through the flow without work parties and then triggering the send email shape and creating the Fix correspondence assignment worked as expected. If the work party details were later updated and the send email shape was triggered again for the Fix correspondence assignment, the error message "No role defined to work object" appeared. This was an issue with the handling of the email flow the second time through: PyCorrPage.pyCorrPartyRole did not have the work object party details which were added to the work object after the fix correspondence assignment was created, and SendSimpleEmail was not designed to handle the email that needs to be retried during the FixCorrespondence flow call. To resolve this, the system will check whether the pyWorkParty property exists prior to calling the PartyCorrPreferences HTML rule.

INC-136208 · Issue 585226

Case history filter added for manual instantiation of Child Case

Resolved in Pega Version 8.5.1

After upgrade from v7.4 to v8.3, creating any child case from a parent case unexpectedly added the audit history "Child case xxxxx has been manually instantiated" to the parent case. In order to make this customizable, an "isHistoryAvailable" function has been added in the 'when' condition of "AddCoveredWork" Activity's "History-Add" Step. This will use the FilterHistory decision tree, which now has a setting for "ChildCaseInsAudit" to control whether or not the manual Instantiation of a Child Case will appear in the case history. The default is "true"; setting it to "false" will suppress the message.

INC-133615 · Issue 581400

Rendering corrected for contextual prompt in Case Type

Resolved in Pega Version 8.5.1

In Case Type with multiple stages, clicking to add step->More at the last stage caused the More menu to be distorted and not usable. Investigation showed that whenever the contextual prompt was opened in this way and the layout had no space on the right side, it shifted left and moved beyond the visible layout. This was traced to the two column layout in pxContextualPromptWithPreview having display styling set to block, and has been resolved by updating this setting to display as table.

INC-132297 · Issue 583956

FlowAction HelpText retained on refresh

Resolved in Pega Version 8.5.1

When a FlowAction configured with HTML was rendered on UI, reloading made the HelpText disappear. Flow action help icon is displayed using pzActionHelp control, which uses the Task Index parameter to determine whether to show the help icon or not. Investigation showed that when pyCaseActionAreaHeader was getting refreshed, this parameter was missed. To resolve this, the pzActionHelp control has been modified to fetch the correct action and index which will be used in displaying the flow action help.