Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-D12530 · Issue 482721

Spinner wheel dom correctly cleared after incomplete case closure

Resolved in Pega Version 8.3

Incorrect behavior of the spinner wheel during a case search following the browser being closed while a case was open has been resolved by updating pzpega_ui_doc_actionRouter to ensure the wheel dom is correctly cleared.

SR-D9683 · Issue 482755

PMML evaluator updated

Resolved in Pega Version 8.3

A null pointer exception was generated when running a predictive model after a PMML import. This was traced to an error in the Regression Evaluator which caused an incorrect calculation for the alternate outcome of a binary model. This has been corrected with an added null check so the "other" value in a binary (logistic) classification model will be correctly evaluated.

SR-D10281 · Issue 482812

Configuration settings introduced for VBD read/write consistency

Resolved in Pega Version 8.3

Exports of VBD data at different consistency levels showed data inconsistency between Cassandra nodes. VBD uses the default DSM consistency level of ONE for its reads and writes, which will not automatically repair data when inconsistency exists. Data inconsistencies can lead to VBD timeouts trying to load partition data. To support VBD read/write integrity, an enhancement has been added to allow configuration of VBD read/write consistency levels by way of the following DSS properties (Owning Ruleset: Pega-DecisionEngine): vbd/readConsistencyLevel and vbd/writeConsistencyLevel. R + W > N where R is the consistency level of read operations, W is the consistency level of write operations, and N is the number of replicas. These will override the default DSM read/write consistency levels (ONE).

SR-D11988 · Issue 483012

TopCase key returned to support case dependency functions

Resolved in Pega Version 8.3

Case dependency was not working if the activity pxCheckFlowDependencies called the pzLoadCaseHierarchywrapper activity which further called the function pzMapCases to populate the pyTopCaseMap page. The page was loaded as expected when the 'when' rule pyEnableTopCaseLinks was false but when Top Case links were enabled, the page was not loaded appropriately. To handle this scenario, the system will return parent case key and class itself if it does not have a parent in pxGetTopLevelCoverKeyAndClass function.

SR-D2887 · Issue 483082

Fixed Export to PDF page formatting

Resolved in Pega Version 8.3

A formatting issue was seen when using export to PDF; the first page contained only the title of the report as well as the filter, the generated date, and the number of records, and the exported data was included only from the 2nd page onwards. This has been corrected, and some performance improvements for the generation time were added.

SR-D1575 · Issue 483120

Added check for null work page in Pulse task

Resolved in Pega Version 8.3

After upgrade, the message "Error in Pega Log file:Unkown Error: Error during while executing pulse task: SingleCaseMetricsManagerFlush java.lang.NullPointerException: null" appeared while executing Pulse task. This was traced to a null workObjectPage, and has been resolved by adding a check for a successfully created work page.

SR-D9242 · Issue 483171

Security improved for DownloadFromServiceExport

Resolved in Pega Version 8.3

In order to improve security, the activity “DownloadFromServiceExport” now requires authentication and explicitly blocks attempts to traverse up directories.

SR-D10867 · Issue 483199

Security improved for DownloadFromServiceExport

Resolved in Pega Version 8.3

In order to improve security, the activity “DownloadFromServiceExport” now requires authentication and explicitly blocks attempts to traverse up directories.

SR-D13880 · Issue 483330

Support added for using WorkPage class for FieldValue evaluation

Resolved in Pega Version 8.3

The Instructions provided under the Assignment details section of an assignment shape were not evaluating the FieldValue for the work object's audit history entries unless the field value was defined only at @baseclass. This was due to WorkPage class not being considered while evaluating a FieldValue, and has been resolved by modifying the InstructionsLookup control to use work class instead of the hard coded @baseclass.

SR-D26642 · Issue 483436

Layout Refresh on Value Change works with Property Empty

Resolved in Pega Version 8.3

Layout refresh on value change was working when changed from "Yes" -> "No" or "No" -> "Yes", but was not triggering the refresh when the first change was from Empty to "Yes" or "No". To resolve this, the pre-replacement event validationType attribute on this function has been removed so an empty value will be processed.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us