SR-D84480 · Issue 546188
FilterHistory decision tree used for audit log status
Resolved in Pega Version 8.5
Attempting to use the “FilterHistory” decision tree in the work class to return value “false” for “pyCloseOpenAssignmentsOnResolution” to hide the “pyCloseOpenAssignmentsOnResolution” field value (“Unfinished assignments were cleaned up by the system after the completion.. ”) from history was not working as expected, and still returned the audit message. This was due to the system setting this AuditNote parameter within the “pzProcessResolutionStage” activity, where Param.UpdateHistory was set to true always. In order to support more flexibility, the Param.updateHistory paramter in step3 of the pzProcessResolutionStage activity will be set based on the FilterHistory decision tree. When set to false in FilterHistory decision tree, pyCloseOpenAssignmentsOnResolution will be set as false and audit will not be logged.
SR-D84754 · Issue 548164
Resolved erroneous problem assignment error
Resolved in Pega Version 8.5
If a user processed a work item while the SLA agent was also attempting to process it, it sometimes resulted in an assignment with the error: "Error: Flow Not At Task." In this scenario, an error message was displayed stating that "Assignment already completed" even though the assignment was not yet finished, causing confusion. Investigation showed that in cases where the success indicator was -28, the assignment was marked as problem assignment even though it was processed. To resolve this, the system has been updated to skip marking the assignment as a problem when the success indicator is -28.
SR-D69081 · Issue 532301
Handling added for null requiredskillcount on assignment
Resolved in Pega Version 8.5
If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.
INC-121435 · Issue 563876
Handling added for null requiredskillcount on assignment
Resolved in Pega Version 8.5
If the property pxRequiredSkillCount was blank on an assignment when moved to a workbasket, it was never presented for Get Next Work. To resolve this, handling has been added which will change the null to 0 so the assignment is properly queued.
SR-D65513 · Issue 533277
URL encryption modified for ShowAllOperators
Resolved in Pega Version 8.5
In the control ShowAllOperators the call to pzEncryptURLActionString was introduced to encrypt URLs to avoid hijacking. The content of the URL relied on the pxRequestor.pxWorkGroup property which was resolved using pega:reference tags. This approach worked in versions below 8.x, but in higher versions the tags were not resolved at runtime and results were not displayed. To resolve this, the requestorWorkGroup will be treated as string and passed as parameter instead of using pega:reference tags.
SR-D73536 · Issue 538402
FetchApplicationLogo modified to Filter by rule resolution
Resolved in Pega Version 8.5
It was observed that the Report Definition rule "pzFetchApplicationLogo", referenced by Activity rule "pzLoadApplicationLogo", always returned the older version of the Binary File "webwb • pyapp-logo • svg" because it had been set to retrieve a maximum of one record and in this case the results were sorted in an order where the oldest record was at the top. As the Report Definition did not indicate any sorting, most DBMS were returning the results in no particular or predictable order. To resolve this, "Filter by rule resolution" has now been enabled for RD pzFetchApplicationLogo.
SR-D68235 · Issue 534782
Stale WorkSearchPreference data cleared when switching apps
Resolved in Pega Version 8.5
The D_pyWorkSearchPreferences data page data was not refreshing while switching between apps, causing stale data to be populated under the case search dropdown for all the applications after switching the application from one to another. This has been resolved by removing the D_pyWorkSearchPreferences data page as part of pzProcessApplicationSwitch.
SR-D88141 · Issue 550009
TemplateButton field correctly set read-only
Resolved in Pega Version 8.5
When a control was added to a section using the DX API, a pyTemplateButton field was added to the XML definition of the section with read-only set to 'false'. This has been corrected so the pyTemplate Button field does not allow input.
SR-D92352 · Issue 553617
Completed onChange will reset FileInput value to null
Resolved in Pega Version 8.5
When attaching a file using the "Select File" button, it was not possible to attach the same file after deleting it. Re-attaching the file worked as expected when using Drag and Drop. Investigation showed that the onchange event occurred only when the value of an element was changed, so in this case trying to attach the same file did not change the value of the element and did not fire the onchange. To resolve this, the value of FileInput in pzMultiFilePath Control will be set to null at the end of the onChange event so that an onChange event will be triggered next time even if the same file is added.
SR-D91834 · Issue 554425
Related cases of different types properly linked in Case Worker Portal
Resolved in Pega Version 8.5
After creating a case of type1 in the Case Worker portal, creating a case of type2 from the first case showed the case ID of the second case in the Related Work section as expected. However, after clicking on the link of the case ID of the second case from the related work section, the second case opened but the case ID of the first case was not shown in the Related work. The cases were correctly associated when the Case Manager portal was used instead. This was traced to the Case Worker clipboard continuing to hold the previous case ID thread, and has been resolved.