SR-A11563 · Issue 224698
XSS security added to data table edits
Resolved in Pega Version 7.2
When editing a data table and saving the record, the request could be intercepted and a vulnerable string added to the pageIndex parameter. XSS security has been added to this function.
SR-A11563 · Issue 224698
XSS security update for TabbedRepeatingListSection
Resolved in Pega Version 7.2
Security updates have been made to the TabbedRepeatingListSection function to close a potential XSS vulnerability.
SR-A3712 · Issue 222263
Removed collapse from advanced filter options to improve accessibility
Resolved in Pega Version 7.2
The advanced options in the report viewer's filter conditions were not accessible using the keyboard and would only expand with a mouse. To resolve this, the advance options collapse has been removed from PZFILTERADVANCEDOPTIONS and the information now fully displayed.
SR-A3712 · Issue 218750
Removed collapse from advanced filter options to improve accessibility
Resolved in Pega Version 7.2
The advanced options in the report viewer's filter conditions were not accessible using the keyboard and would only expand with a mouse. To resolve this, the advance options collapse has been removed from PZFILTERADVANCEDOPTIONS and the information now fully displayed.
SR-A8488 · Issue 219112
HTML line breaks honored in Excel export
Resolved in Pega Version 7.2
In Report Definition, Export to Excel was ignoring the new line of each cell due to pzDisplayPropValue not acting on the HTML tag
. To correct this, the call to the function "pzDisplayPropValue" has been modified to pass a flag which will be set based on option given on the RD rule form, i.e. "Ignore formatting when Exporting to Excel". In addition, the
tag is now supported so Excel will format it accordingly.
SR-A8488 · Issue 220333
HTML line breaks honored in Excel export
Resolved in Pega Version 7.2
In Report Definition, Export to Excel was ignoring the new line of each cell due to pzDisplayPropValue not acting on the HTML tag
. To correct this, the call to the function "pzDisplayPropValue" has been modified to pass a flag which will be set based on option given on the RD rule form, i.e. "Ignore formatting when Exporting to Excel". In addition, the
tag is now supported so Excel will format it accordingly.
SR-A9731 · Issue 222614
Pick a Value window resized for proper display
Resolved in Pega Version 7.2
On clicking on the criteria field of any report (listview / SummaryView), the 'Pick Values' modal window opens up for user to select values. This window is sized smaller by a percentage than the ClientHeight to ensure the popup can display the content within the height of the current window. After upgrade, the modals appeared with a default height of 96% and caused the Apply / Cancel / Submit buttons to either be partially visible or not visible at all, which did not allow user to select values. This has been resolved by updating the "launchpickavalue" method defined in "Rule-Obj-HTML.Wizard_Parameters" rule to set the iframe height to 93%.
SR-A9198 · Issue 218533
Text retrieval for deprecated "Query" button updated for universal browser support
Resolved in Pega Version 7.2
The Firefox popup window provided by the Product rule when querying "Individual Instances to Include" failed to transpose the selected rule information back into the Product ruleform when the OK button was clicked. This was due to the use of the deprecated "Query" button, which does not have support for all browsers, to launch the ListView. To handle this, the node text retrieval method in DataInstancesQueryScript has been updated to use the 'textContent' function (compatible with all browsers) instead of the previous 'innerText'.
SR-A10839 · Issue 222017
Added handling for null rollback info in hotfix autocommit
Resolved in Pega Version 7.2
If AutoCommit was selected while installing a hotfix, the auto-commit would fail and leave the hotfix in an Uncommitted state if there were dependent hotfixes where changes were covered by the parent and the child was superseded after installing the parent. Manual commitment of the hotfix worked as expected. This was an edge case where the older hotfix did not get rollback information saved since its components were already installed or superseded, and AutoCommit has been updated to handle this missing information.
SR-A10327 · Issue 222830
Upgrade Assistant enhanced to better resume interrupted process
Resolved in Pega Version 7.2
If the system suffered a crash during upgrade, IUA was incorrectly identifying the DB as having completed the upgrade and would import outstanding rules based on the perceived Database BLOB version. This led to a storage-type mismatch between Prod and all lower environments, and BIX jobs would fail due to not being upgraded. An enhancement has been added to the Upgrade Assistant to correctly resume an interrupted upgrade process.