Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please note: beginning with the Pega Platform 8.7.4 Patch, the Resolved Issues have moved to the Support Center.

SR-A619 · Issue 205442

Page Messages displayed on dropdown after render

Resolved in Pega Version 7.1.9

When submitting a flow action that contains a dropdown control and which is configured to load its values after the screen renders, Page Messages were not displayed when the flow action was re-displayed. This was caused by "pzKeepPageMessages" not being set to "true" while sending the ajax request to fetch drop down options (for render after screen/load on hover), and has been corrected.

SR-A642 · Issue 206621

Enabled section autogeneration from HTML to JSP

Resolved in Pega Version 7.1.9

Effective with Pega7, section generation was changed from HTML(pyJavaGenerateAPIVersion = 04-01) to JSP(pyJavaGenerateAPIVersion = 04-02). This caused an issue with some migrations from earlier versions that were not able to make the mandatory switch from HTML to JSP generation due to a missing option in the section ruleform. The option to upgrade from HTML to JSP had been configured from within "pyAutoHTML = false", meaning that this option appeared only for non-autogenerated sections. To resolve this, the option "Generate for" in the section Rule-HTML-Section.pzRuleFormHTML is now available irrespective of whether pyAutoHTML is set to true or false.

SR-A681 · Issue 205448

Added handling for empty section name in reload

Resolved in Pega Version 7.1.9

A Null message was sporadically displayed when hovering over a row instead displaying the SmartInfo section or a loading icon. This was caused by an empty section name in the reload section ajax, and handing for this has been added to the SmartHarness API.

SR-A833 · Issue 204781

Fixed Google Chrome 43 population of Dynamic Select and Menu control

Resolved in Pega Version 7.1.9

When using Google Chrome Version 43.0.2357.81 m, no values were shown in the Dynamic Select drop down list or in the Menu control. This was due to an uncaught exception for this browser in the JavaScript code which has now been addressed.

SR-A91 · Issue 205459

Added expand on click logic to check for layouts collapsed on open

Resolved in Pega Version 7.1.9

The ?Expand/Collapse? click event was not working on the first click if all layouts/sections were initially collapsed on open. This was due to the logic used to determine the state of the layouts, and an additional check has been inserted to handle scenarios where the layouts/sections are collapsed on-load.

SR-A2640 · Issue 207012

Corrected field limit size on mobile

Resolved in Pega Version 7.1.9

When using an Android mobile device, the max number of characters for an input field was not being honored. This has been corrected.

SR-A3072 · Issue 204300

Attachment visibility fixed for mobile devices

Resolved in Pega Version 7.1.9

When attachments were uploaded to a mobile device, they were not immediately visible and required a refresh to be displayed. This was found to be an issue in the signature control and Attach content control where the data page referred to in the attachments display was not removed when a new attachment is added. For this release, the data page removal part has been moved to the saveattachment activity. In the next release, all attachment controls will call an API designed for that purpose.

SR-A3072 · Issue 204019

Attachment visibility fixed for mobile devices

Resolved in Pega Version 7.1.9

When attachments were uploaded to a mobile device, they were not immediately visible and required a refresh to be displayed. This was found to be an issue in the signature control and Attach content control where the data page referred to in the attachments display was not removed when a new attachment is added. For this release, the data page removal part has been moved to the saveattachment activity. In the next release, all attachment controls will call an API designed for that purpose.

SR-D47146 · Issue 515647

Pick Values modal updated for deprecated list view handling

Resolved in Pega Version 8.1.8

Pick values were not displaying in the menus below Case Management-> Tools -> My Work, including "Work entered by me", "Work by workbasket", and "Work resolved by me recently". This was due to the use of deprecated list views: the pick values modal was failing to show and hide the busy indicator because the indicator now uses jQuery, but list view does not include jQuery. In order to resolve this, the equivalent Report Definition pyEnteredByMe has now been added under the navigation rule : pzProcessAndCaseRulesMainMenu.

SR-D59504 · Issue 524641

Attachment drag drop searches only current Ajax context

Resolved in Pega Version 8.1.8

When the Interaction for customer service was open and more than 1 task from the sidebar was open, the drag and drop zone was missing on any subsequent Task/Cases past the first. In an Ajax container scenario, getElementByID js was searching in all the containers because they were present in DOM, and it was losing context. To resolve this, the code has been updated to only search in the current context when using an Ajax container.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us