SR-126980 · Issue 192477
Chart control validation updated to handle aggregate functions
Resolved in Pega Version 7.1.8
When a chart control contained a Report definition with COUNTDISTINCT in the summarize field, the chart was not displayed at runtime. Manually executing the Report Definition displayed the data and the pie chart as expected. This was found to be an issue with chart control not rendering the chart at run time if the underlying RD source contained an aggregate function. To correct this, the pzIsChartReportColumnValid validate rule has been updated.
SR-126980 · Issue 190876
Chart control validation updated to handle aggregate functions
Resolved in Pega Version 7.1.8
When a chart control contained a Report definition with COUNTDISTINCT in the summarize field, the chart was not displayed at runtime. Manually executing the Report Definition displayed the data and the pie chart as expected. This was found to be an issue with chart control not rendering the chart at run time if the underlying RD source contained an aggregate function. To correct this, the pzIsChartReportColumnValid validate rule has been updated.
SR-126986 · Issue 197102
Added class handling for creation of embedded pages with page-new method
Resolved in Pega Version 7.1.8
After upgrade, an error was generated while using page-new method to create a new page unless the default page class was present. This occurred when an embedded property was created using page-new with a class that is a child class of the defined embedded class and the parent property of that embedded property was auto-populate/special-java. This was caused by the class being different than the defined embedded class, meaning it was considered as a change to pxObjClass (which is not allowed) and it was not handled. To resolve this, a check has been added to set the right class when creating a embedded page by page-new, using the class of the input page when setting value of a embedded property instead of the defined class if present in input page.
SR-127017 · Issue 189834
Resolved window resizability for harness launched in a pop up
Resolved in Pega Version 7.1.8
Using pxButton to launch a harness in a pop up window generated a window with the maximize button disabled and no way to resize. This was caused by the resizable argument not being passed to the popup window when launching the harness, and the GenerateControlAction has been modified to pass this to the popup window.
SR-127035 · Issue 193206
Improved opening custom flow rules with Microsoft Internet Explorer 9
Resolved in Pega Version 7.1.8
Opening up a flow rule with many sub-process references was taking an excessive amount of time when using Microsoft Internet Explorer 9 due to general browser slowness and the system loading all referenced flow rules at that time. This has been resolved by tuning the JavaScript code to improve the performance of the viewer and to disable drilldown functionality from the server.
SR-127039 · Issue 190388
Resolved error with Obj-Refresh-And-Lock Method for results browse
Resolved in Pega Version 7.1.8
If the useLightweight List checkbox was checked when trying to do an obj-browse, Obj-Refresh-And-Lock method was generating an error. This was an issue with the virtual clipboard, and has been resolved.
SR-127042 · Issue 190334
Localization added for Operator profile values
Resolved in Pega Version 7.1.8
Localization has been added for the Operator profile full display custom labels.
SR-127091 · Issue 193209
Forward chaining commit error resolved
Resolved in Pega Version 7.1.8
A sporadic pyCommitError was observed when performing 'Action' during a 'Phone call' interaction for a specific user. During forward chaining, a malformed variable change that occurs when a page copy happens on a embedded page of a work page is recreated in order to not corrupt the fragment collection cache. Previously, this was done only while evaluating the declare expressions. The system has now been updated to do the same during evaluation of other declarative flavors during forward chaining.
SR-127121 · Issue 193264
Gauge Dial display in Case Manager updated for Microsoft Internet Explorer 8
Resolved in Pega Version 7.1.8
After clearing the browser cache in Microsoft Internet Explorer 8 and logging into the case manager portal, the gauge dials disappeared. On relogin they appeared properly. This issue was due to the style attribute positioning being incorrectly represented in Microsoft Internet Explorer 8, and has been adjusted.
SR-127130 · Issue 192558
Localization added for filter values accessed from a new locale
Resolved in Pega Version 7.1.8
After building a Report Definition that used a custom section to display filter values, localization for the filter values was not working if a user logged in with a different locale. Code has been added to handle localizing filter value and label in this situation.