SR-C82480 · Issue 421488
Column Headers properly aligned after expand/collapse of Tree Grids
Resolved in Pega Version 8.1.3
When using a hierarchical table - tree grid with a configuration that included Width of content-Pixels(Fit Content), a Fixed (pixel) size grid, and Freeze Header, expanding and collapsing back the contents resulted in a misalignment of the column headers. The fixed header implementation makes use of multiple table layouts which have to kept in sync via javascript; this issue has been resolved by rewriting the fixed header implementation to call setHeadersWidth on expand/collapse of a treegrid row.
SR-C82530 · Issue 420609
Atmosphere XSS Vulnerability fixed
Resolved in Pega Version 8.1.3
Atmosphere has been updated to close a potential XSS vunerability.
SR-C83808 · Issue 421299
FIRST aggregate in bucketed window fixed
Resolved in Pega Version 8.1.3
FIRST aggregates were not giving the correct results if used in a Sliding Time window together with an average aggregate.This was traced to an incorrect implementation of FirstAggregatorHolder.substractAggregate which used propertyIndex to get aggregate value (which was not correct in this context), and has been fixed by using the correct index in FirstAggregatorHolder class.
SR-C83915 · Issue 421169
Enhancement added to support property reference name for section include
Resolved in Pega Version 8.1.3
When requesting the view of a section from a repeating dynamic layout where the name of the section is taken from a property, the DX API returned an error on the tracer indicating "Invalid value for aReference passed to com.pega.pegarules.data.internal.clipboard.ClipboardPageImpl.getString(String)". This has been resolved by adding an enhancement to support using a property reference for section include.
SR-C85035 · Issue 421948
Added getIfPresent check for Field Value parameters with pzAPICreateJsonForView
Resolved in Pega Version 8.1.3
Calling pzAPICreateJsonForView was altering case values if localized field value parameters were added. This has been corrected by performing a getIfPresent and getIfString on the property pyFieldValueParams so field value parameters will not be added to the main page if they're not present.
INC-135335 · Issue 588510
Parent flow next step will take precedence over sub-process
Resolved in Pega Version 8.5.1
A Breadcrumb configured in the screen flow was not displaying at the last assignment when there were multiple embedded sub processes and the last assignment was called in a sub process. This was traced to the parent flow next step information not being passed due to the next step in the sub process being marked as an end shape. To resolve this, the pzFlowSteps7 html control has been updated to pass the parent flow's next step information in this situation.
SR-D77719 · Issue 569769
OpenIfStale updated to resolve optimistic locking race condition
Resolved in Pega Version 8.5.1
A race condition was created in optimistic locking by having two assignments save at overlapping times. This has been resolved by modifying the pzShowConflicts activity to use a version of openIfStale which will consider a workpage as stale even if the difference in pxUpdateDatetime is in milliseconds.
INC-134912 · Issue 581326
Handling updated for wait shapes with different outgoing connector flow actions
Resolved in Pega Version 8.5.1
After configuring a flow with a wait shape that by default used the pyContinueAfterWait flow action for the outgoing connector of the wait shape refer, adding any other valid flow action resulted in the error "Action To Take must be a valid flow action for this assignment". This was due to the post-processing of the connector properties modal updating the ActionToTake value based on wait shape, so that changing the flow action on a connector caused the validation on save to fail if the ActionToTake on wait shape and the connector flow action did not match. To resolve this, the system has been modified to validate a wait shape with different flow action on the outgoing connector.
SR-D59283 · Issue 523207
Check added for WorkParty property to catch changes
Resolved in Pega Version 8.5.1
After configuring a send email shape to send email to work parties, proceeding through the flow without work parties and then triggering the send email shape and creating the Fix correspondence assignment worked as expected. If the work party details were later updated and the send email shape was triggered again for the Fix correspondence assignment, the error message "No role defined to work object" appeared. This was an issue with the handling of the email flow the second time through: PyCorrPage.pyCorrPartyRole did not have the work object party details which were added to the work object after the fix correspondence assignment was created, and SendSimpleEmail was not designed to handle the email that needs to be retried during the FixCorrespondence flow call. To resolve this, the system will check whether the pyWorkParty property exists prior to calling the PartyCorrPreferences HTML rule.
INC-136208 · Issue 585226
Case history filter added for manual instantiation of Child Case
Resolved in Pega Version 8.5.1
After upgrade from v7.4 to v8.3, creating any child case from a parent case unexpectedly added the audit history "Child case xxxxx has been manually instantiated" to the parent case. In order to make this customizable, an "isHistoryAvailable" function has been added in the 'when' condition of "AddCoveredWork" Activity's "History-Add" Step. This will use the FilterHistory decision tree, which now has a setting for "ChildCaseInsAudit" to control whether or not the manual Instantiation of a Child Case will appear in the case history. The default is "true"; setting it to "false" will suppress the message.