INC-202480 · Issue 699080
Resolved report filter section freeze
Resolved in Pega Version 8.5.6
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
INC-137352 · Issue 583664
Mobile app improvements for poor connectivity conditions
Resolved in Pega Version 8.5.1
When the mobile app was used in areas with poor data network connectivity, the screen was freezing or a number of sync errors were seen. Improvements have been made in the processing and wait conditions to smooth the functions when connectivity is intermittent.
INC-136057 · Issue 587164
Modal dialog close for date/time works as expected
Resolved in Pega Version 8.5.1
When a date/time property was used in a modal screenflow in Google Chrome, changing the date property on the pop up calendar and then clicking the modal close caused the screen to freeze. This was caused by the plf.handleModalClose() being called a second time for a container close event that was not available in window.event. This has been resolved.
SR-116479 · Issue 170952
Elapsed Time reporting corrected
Resolved in Pega Version 7.1.7
Two out-of-the-box reports, Elapsed Status Time Trend and Average Elapsed Time Per Status, were causing the browser to freeze and stop responding if there were more than 1000 records. This was caused by an invalid value for the datetime units on the category for the chart causing looping behavior. This has been corrected.
SR-115749 · Issue 167027
Support added for custom filtering and refresh inside a Repeat Grid
Resolved in Pega Version 7.1.7
If a dropdown control was placed in the column header of a repeating grid to work as a filter and perform a section refresh for the list (based on a column present in the list, but not displayed in the grid), checking the option to freeze the column headers (and use a fixed height/width) caused the dropdown to no longer work and no refresh action could be triggered. This was caused by a second hidden dropdown in the grid with the fixed header configuration that overwrote the selected value in the ASYNC request that is sent when the dropdown value changes. To remedy this, changes were made in the HTML generation to make the hidden header input disabled. This works only when configured as "auto": the control generation logic overwrites all readonly conditions to true if the dropdown is configured as "Editable".