INC-197358 · Issue 695309
Resolved finish assignment screen freeze
Resolved in Pega Version 8.6.3
In some assignments of several flows, when the processing was done (finish assignment) the screen only displayed the loading logo. The only way to proceed was by refreshing the browser. The browser console showed the error "Uncaught TypeError: Cannot read properties of null (reading 'undefined') at setTargetValuesSuccess (expression_calculation_1480665478.js!!.js:1) at k". The error did not occur when using Live UI privileges. This has been resolved by updating the expression calculation.
INC-202480 · Issue 699080
Resolved report filter section freeze
Resolved in Pega Version 8.5.6
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
INC-202480 · Issue 711699
Resolved report filter section freeze
Resolved in Pega Version 8.7.2
When opening a report with a count column, changing the order of one of the report columns resulted in the report freezing and requiring the report to be closed and re-run. This was traced to a double filter popup appearing that did not close after the column sorting, which happened if the report definition was configured as a summary with an aggregated column such as "Count” combined with a "Do not display group headings" setting on the Report Viewer tab. To resolve this, a new step has been added in the Activity pzPopulateSortOrder to call the pzCancelFilterLogicChanges activity.
INC-217655 · Issue 723564
Resolved validation check freeze for Dynamic Layout Group
Resolved in Pega Version 8.6.5
After creating a multi-step form where step 1 had a Dynamic Layout Group(tabbed) that used form fields configured with validations, clicking next with empty/invalid values in the form intermittently caused the screen to freeze and a javascript exception was logged. This was traced to a missed use case related to templates in the childNode, and has been resolved by adding the necessary safe checks in lgtemplate and lgcelltemplate.
INC-208199 · Issue 706446
Added input null check to resolve loading error
Resolved in Pega Version 8.7.2
The application was freezing while loading if action was taken on the controls while a page level message was visible. This has been resolved by adding an additional null check for input before calling the focus API.
SR-116479 · Issue 170952
Elapsed Time reporting corrected
Resolved in Pega Version 7.1.7
Two out-of-the-box reports, Elapsed Status Time Trend and Average Elapsed Time Per Status, were causing the browser to freeze and stop responding if there were more than 1000 records. This was caused by an invalid value for the datetime units on the category for the chart causing looping behavior. This has been corrected.
SR-115749 · Issue 167027
Support added for custom filtering and refresh inside a Repeat Grid
Resolved in Pega Version 7.1.7
If a dropdown control was placed in the column header of a repeating grid to work as a filter and perform a section refresh for the list (based on a column present in the list, but not displayed in the grid), checking the option to freeze the column headers (and use a fixed height/width) caused the dropdown to no longer work and no refresh action could be triggered. This was caused by a second hidden dropdown in the grid with the fixed header configuration that overwrote the selected value in the ASYNC request that is sent when the dropdown value changes. To remedy this, changes were made in the HTML generation to make the hidden header input disabled. This works only when configured as "auto": the control generation logic overwrites all readonly conditions to true if the dropdown is configured as "Editable".