Skip to main content

Resolved Issues

View the resolved issues for a specific Platform release.

Go to download resolved issues by patch release.

Browse release notes for a selected Pega Version.

NOTE: Enter just the Case ID number (SR or INC) in order to find the associated Support Request.

Please update your bookmarks. This site will be discontinued in Dec 2024.

Pega Platform Resolved Issues for 8.1 and newer are now available on the Support Center.

SR-D83373 · Issue 545751

Fusion Charts upgraded

Resolved in Pega Version 8.5

Fusion has been upgraded to version 3.15.1-sr.1

SR-D94002 · Issue 553767

Export to Excel cell style control added

Resolved in Pega Version 8.5

If a column was formatted with an auto generated numeric control, a new cell style was generated for every row during the export to Excel process. Since there is a limit on the amount of cell styles, once the number of rows in the file was greater than 64000 an error was generated. To resolve this, the system will disable the creation of a new cell style for every instance when an auto-generated numeric control is used.

SR-D64231 · Issue 539234

Export to Excel cell style control added

Resolved in Pega Version 8.5

If a column was formatted with an auto generated numeric control, a new cell style was generated for every row during the export to Excel process. Since there is a limit on the amount of cell styles, once the number of rows in the file was greater than 64000 an error was generated. To resolve this, the system will disable the creation of a new cell style for every instance when an auto-generated numeric control is used.

SR-D71408 · Issue 534934

DIrty check flag triggered by adding columns and filters

Resolved in Pega Version 8.5

If a report was edited and closed without saving, the dirty check worked as expected. However, if new columns or filters were added and the report closed without saving, the dirty check did not appear. This has been resolved by updating the check logic.

SR-D86864 · Issue 548093

Very long auto-generated index trimmed for use in Report Browser

Resolved in Pega Version 8.5

The creation of a new report via the user report browser failed if there was an index with a long name (over 30 characters). The OOTB method automatically generated the prefix, but the Report editor could not handle the very long declare index name and as a result did not consider properties from the embedded pages. To resolve this, pzUpdateAssociation and pzInsertNewReportColumn have been updated to trim the prefix for the declare index to 30 characters and allow for adding a new column to the report. This work does not cover adding a new filter to the report, as that fix would require substantial changes to reporting logic.

SR-D53176 · Issue 541795

Error when adding function filter will persist

Resolved in Pega Version 8.5

When an exception occurred while adding a filter in the report viewer, the error was shown but cleared due to an immediate refresh of the parent section. Analysis found that step2 of pzGetFiltersFromContent was failing, after which the error was shown, the section reload happened, and the error disappeared. To resolve the error being cleared prematurely, the pzOnLoadReloadReport control has been modified so that when there are messages on the top level page (pyReportContentPage), a parameter will be set on HarnessContextMgr to not to clear them during the next refresh call.

SR-D73777 · Issue 539969

Logic added for client-side Somaria decoding

Resolved in Pega Version 8.5

When Somaria (an Advanced Data Visualization control) was used with Predictor Performance, the special characters were displayed as ASCII values instead of the actual values in the label. This was traced to Somaria encoding special characters of the visualization data into HTML entities on the server in order to protect against cross-site scripting attacks, but these entities were not being decoded on the client side. To resolve this, logic has been added to decode HTML entities in Somaria data on the client.

SR-D80589 · Issue 544841

Check added before clearing Report definition custom filter section page

Resolved in Pega Version 8.5

When using a Custom Section in the Report Viewer, the Page referred to at the Prefix was getting reset while running the report. Investigation showed the page was being reinitialized in pzCreateCustomFilterPage step 2, and this has been resolved by adding a 'when' rule for clearing the custom filter page.

SR-D87898 · Issue 552589

SaveAttachment Activity in Data-WorkAttach-URL updated

Resolved in Pega Version 8.5

A 'when' condition was not properly evaluated for Activity SaveAttachment (CL:Data-WorkAttach-URL ), causing the Next assignment screen to not be displayed. This has been resolved by modifying the handling of Page Names used as activity parameters to remove the use of the specific PageName "pyAttachmentPage" in the operation and make it generic to Primary in the SaveAttachment Activity of CL: Data-WorkAttach-URL.

SR-D64506 · Issue 529334

Improved accessibility around page landmarks

Resolved in Pega Version 8.5

Accessibility testing revealed an issue with pages where the main landmark was contained in another landmark. This has been resolved by removing the main role in the FlowActionHTML rule.

We'd prefer it if you saw us at our best.

Pega.com is not optimized for Internet Explorer. For the optimal experience, please use:

Close Deprecation Notice
Contact us